Troubleshoot the safe torque-off function – Rockwell Automation 2198-Hxxx Kinetix 5500 Servo Drives User Manual User Manual

Page 170

Advertising
background image

170

Rockwell Automation Publication 2198-UM001D-EN-P - May 2014

Chapter 10

Kinetix 5500 Safe Torque-off - Integrated Safety

Refer to

Figure 73

for an understanding of the 2198-H

xxx-ERS2 STO state

restart functionality.

Figure 73 - Kinetix 5500 STO Timing Diagram

Troubleshoot the Safe Torque-off Function

Table 78 - 2198-Hxxx-ERS2 Servo Drive Troubleshooting

IMPORTANT

2198-Hxxx-ERS2 servo drives enter the STO state if any STO function fault is
detected. Refer to

Table 78

for integrated safety troubleshooting.

Drv:SO.SafeTorqueOff

Drv:SO.Reset

Drv:SI.ResetRequired

Drv:SI.TorqueDisabled

Axis.SafeTorqueOffActiveStatus

Axis.SafeTorqueOffActiveInhibit

Axis.SafeTorqueDisabledStatus

Safe Torque-off Request

Axis.SafetyResetRequestStatus

Axis.SafetyResetRequiredStatus

Reset Request

Exception Code on Drive Display

Fault Message
Logix Designer

Problem

Possible Solutions

SAFE FLT S01- Safety Core Internal

CPUWatchdogFault

(1)

Drive safety diagnostic detected internal
STO design failure.

Cycle control power
Return drive for repair if fault continues

SAFE FLT S03- Safe Torque Off

SafeTorqueOffFault

(2)

Drive safety diagnostic detected internal
STO design failure.

Cycle control power
Execute STO function
Return drive for repair if fault continues

(1) Displayed in the Quick View Pane as Module Fault.
(2) Displayed in the Quick View Pane as Safety Fault.