Shared-bus configurations, Appendix c, Sizing multi-axis shared-bus configurations – Rockwell Automation 2198-Hxxx Kinetix 5500 Servo Drives User Manual User Manual

Page 213: Appendix

Advertising
background image

Rockwell Automation Publication 2198-UM001D-EN-P - May 2014

213

Appendix

C

Sizing Multi-axis Shared-bus Configurations

This appendix provides information and examples for sizing your Kinetix 5500
drive shared-bus configurations.

Shared-bus configurations include the following types:

Shared AC
Shared DC (common bus)
Shared AC/DC
Shared AC/DC Hybrid

These restrictions apply to all shared-bus configurations:

Shared-bus configurations must use the shared-bus connection system.

Single-phase drive operation is not supported.
Shared AC/DC and shared AC/DC hybrid configurations result in a

derating of 30% of the total converter power available.

The zero-stack tabs and cutouts must be engaged from drive-to-drive.

Systems cannot start in one cabinet and end in another.

Program drives for the same converter AC input voltage.

Shared-bus Configurations

Shared AC configurations are configured as Standalone in the project file and do
not share these restrictions that apply to multi-axis shared-bus configurations:

All drives in a bus-sharing group must be configured with the same bus

power-sharing group number in the Logix Designer application.

The maximum number of drives in any bus power-sharing group cannot

exceed eight.

Topic

Page

Shared-bus Configurations

213

Power Sharing Sizing Examples

218

Control Power Current Calculations

220

Energy Calculations

222

IMPORTANT

Do not make drive-to-drive connections with discrete wires.

Advertising