Table 58 - INIT FLT Fault Codes

Exception Code on Display

Exception Text

Problem

Possible Solutions

INIT FLT M01 – ENCODER DATA

Smart Encoder Data Corruption

The data stored in the encoder has a checksum error.

• Cycle control power
• Return motor for repair if fault continues

INIT FLT M02 – MTR DATA RANGE

Motor Data Range Error

A motor data attribute stored in the encoder is out of
range.

• Cycle control power
• Return motor for repair if fault continues

INIT FLT M03 – MTR ENC STARTUP

Motor Feedback Communication
Startup

Communication with the encoder could not be
established.

• Cycle control power
• Check motor feedback connector
• Check motor power and feedback shield terminations on the drive
• Return motor for repair if fault continues

INIT FLT M14 – SAFETY FIRMWARE

Safety Firmware

The loaded Safety firmware is not compatible with the
drive firmware.

• Cycle control power
• Update the drive firmware
• Return drive for repair if fault continues

INIT FLT M20 – UNKNOWN
MODULE

Unknown Module

The product code of the power board is invalid.

• Cycle control power
• Reset the drive
• Return drive for repair if fault continues

Table 59 - INHIBIT Fault Codes

Exception Code on Display

Exception Text

Problem

Possible Solutions

INHIBIT S02 – MOTOR NOT
CONFIGURED

Motor Not Configured

The motor has not been properly configured for use.

Verify motor configuration in the Logix Designer application.

INHIBIT S03 – FEEDBACK NOT
CONFIGURED

Feedback Not Configured

The feedback has not been properly configured for
use.

Verify feedback configuration in the Logix Designer application.

INHIBIT M05 – SAFE TORQUE OFF

Start Inhibit – Safe Torque Off

The safety function has disabled the power structure.

• Check safety input wiring
• Check state of safety devices

Table 60 - NODE FLT Fault Codes

Exception Code on Display

Exception Text

Problem

Possible Solutions

NODE FLT 01 – LATE CTRL UPDATE

Control Connection Update Fault

Several consecutive updates from the controller have
been lost.

• Remove unnecessary network devices from the motion network
• Change network topology so that fewer devices share common

paths

• Use high performance network equipment
• Use shielded cables
• Separate signal wiring from power wiring

NODE FLT 02 – PROC WATCHDOG nn

Processor Watchdog Fault

The processor on the power board or control board
failed to update in a certain amount of time.
The nn sub-codes 00…06 are internal and result in
the same possible solution.

• Cycle control power
• Update the drive firmware
• Return drive for repair if fault continues

NODE FLT 03 – HARDWARE 00

Hardware Fault -PwrIF

Communication with the power board could not be
established.

• Cycle control power
• Update the drive firmware
• Return drive for repair if fault continues

NODE FLT 03 – HARDWARE 01

Hardware Fault - Power Board

DSP chip on the power board failure.

• Cycle control power
• Return motor for repair if fault continues

NODE FLT 03 – HARDWARE 02

Hardware Fault - DSL

Communication with the encoder could not be
established.

• DSL feedback wiring is incorrect (check against wiring diagram)
• DSL feedback wiring is shorted or open
• DSL feedback cable is defective
• Kinetix VP motor feedback device is defective
• Cycle power
• Return drive for repair if fault continues

NODE FLT 03 – HARDWARE 03

DSL Internal Hardware Fault

A DSL hardware error internal to the drive was
detected.

• Check DSL feedback device, wiring, and cable
• Cycle power
• Return drive for repair if fault continues

NODE FLT 03 – HARDWARE 04

Hardware Fault - Board
Compatibility

The control and power boards are incompatible.

Return drive for repair if fault continues

NODE FLT 05 – CLOCK SKEW FLT

Clock Skew Fault

The controller time and the drive's system time are
not the same.

• Cycle control power
• Check controller and Ethernet switch operation