Rockwell Automation 2198-Hxxx Kinetix 5500 Servo Drives User Manual User Manual

Page 51

Advertising
background image

Rockwell Automation Publication 2198-UM001D-EN-P - May 2014

51

Mounting the Kinetix 5500 Drive System

Chapter 3

These hole patterns apply when all drives in the system are frame 1 or frame 2.
There is 50 mm (2.0 in.) between mounting holes (A-to-A and B-to-B).

Figure 23 - Frame 1 and Frame 2 Hole Patterns

16x

ØM4 (#8-32)

Axis 1

Axis 3

F

rame 1

193.68

(7.6)

F

rame 2

243.84

(9.6)

Axis 4

Axis 5

Axis 6

Axis 7

Axis 8

Axis 2

A

B

A

B

A

B

A

B

A

B

A

B

A

B

A

B

0

0

50.0 (2.0)

50.0 (2.0)

Frame S

ize

D

imen

sio

n

A

xi

s 1

A

xi

s 2

A

xi

s 3

A

xi

s 4

A

xi

s 5

A

xi

s 6

A

xi

s 7

A

xis 8

1

A

4.51 (0.2

)

54.51

(2

.1)

104.5

1 (4.1)

154.5

1 (6.1)

204.5

1 (8.1)

254.5

1 (10.0

)

304.5

1

(12.0

)

354.5

1

(14.0

)

B

0

50.0

(2.0

)

100.0

(3

.9)

150.0

(5

.9)

200.0

(7

.9)

250.0

(9

.8)

300.0

(1

1.8)

350.0

(1

3.8)

2

A

5.00

(0.2

)

60.0

(2.4

)

115.0

(4

.5)

170.0

(6

.7)

225.0

(8

.9)

280.0

(1

1.0)

335.0

(1

3.2)

390.0

(1

5.4)

B

0

55.0

(2.2

)

110.0

(4

.3)

165.0

(6

.5)

220.0

(8

.7)

275.0

(1

0.8)

330.0

(1

3.0)

385.0

(1

5.2)

Dim

ens

io

ns

are

in

mm (

in

.)

Advertising