Rockwell Automation Publication 2198-UM001D-EN-P - May 2014

227

Induction Motor Support

Appendix D

Table 93 - Skip Frequency Examples

Acceleration and deceleration are not affected by the skip frequencies. Normal
accel/decel proceeds through the band.

Skip Band Description

Graphic Illustration

The skip frequency has hysteresis so the
output does not toggle between high
and low values. You can program three
distinct bands. If none of the skip bands
touch or overlap, each band has its own
high/low limit.

If the band is outside of the limits, the
skip band is inactive.

0 Hz

Frequency, max

Skip Frequency

Skip Band

0 Hz

400 Hz

Skip Frequency

60 Hz Frequency,

max

Inactive
Skip Band