Feedback specifications, Absolute position feature – Rockwell Automation 2198-Hxxx Kinetix 5500 Servo Drives User Manual User Manual

Page 65

Advertising
background image

Rockwell Automation Publication 2198-UM001D-EN-P - May 2014

65

Connector Data and Feature Descriptions

Chapter 4

Feedback Specifications

The Kinetix 5500 drive accepts motor feedback signals from Stegmann
Hiperface digital-servo-link (DSL) encoders.

Kinetix 5500 drive and Kinetix VP motor combinations use single motor-cable
technology with motor power, feedback, and brake wires (when specified)
housed in a single cable. Feedback and brake wires are shielded separately and
each provide a shield braid for grounding in the motor cable clamp.

Table 28 - Stegmann Hiperface DSL Specifications

Other Allen-Bradley motors and actuators with Stegmann Hiperface single-turn
or multi-turn high-resolution absolute encoders are also accepted, but only when
using drive firmware revision 2.002 or later and the 2198-H2DCK Hiperface-to-
DSL feedback converter kit for Hiperface-to-DSL conversion.

Absolute Position Feature

The drive’s absolute position feature tracks the position of the motor, within the
multi-turn retention limits, while the drive is powered off. The absolute position
feature is available with only multi-turn encoders.

Table 29 - Absolute Position Designator Examples

Figure 34 - Absolute Position Retention Limits

TIP

Auto-configuration in the Logix Designer application of intelligent absolute,
high-resolution encoders is possible with only Allen-Bradley motors.

Attribute

Value

Protocol

Hiperface DSL

Memory support

Programmed with Allen-Bradley motor data

Hiperface data communication

9.375 Mbits/s

Encoder Type

Cat. No.
Designator

Cat. No. Examples

Motor Family

Stegmann Hiperface (DSL)

-P

VPL-xxxxxx-P, VPF-xxxxxx-P, VPS-xxxxxx-P

Kinetix VP

Stegmann Hiperface

-M

MPL-B310P-M, MPM-xxxxxx-M, MPF-xxxxxx-M,
MPS-xxxxxx-M, MPAR-x3xxxx-M, MPAI-xxxxxxM

MP-Series

-V

MPL-B230P-V, MPAS-xxxxx1-V05, MPAS-xxxxx2-V20,
MPAR-x1xxxx-V, MPAR-x2xxxx-V, MPAI-xxxxxxV

Stegmann Hiperface (magnetic scale)

-xDx

LDAT-Sxxxxxx-xDx

LDAT-Series

+2048

-2048

+1024

-1024

Position at Power Down

2048 Turns, MP-Series and LDAT-Series Motors/Actuators

4096 Turns, Kinetix VP Motors