Cable categories for kinetix 5500 systems – Rockwell Automation 2198-Hxxx Kinetix 5500 Servo Drives User Manual User Manual

Page 40

Advertising
background image

40

Rockwell Automation Publication 2198-UM001D-EN-P - May 2014

Chapter 2

Planning the Kinetix 5500 Drive System Installation

Cable Categories for Kinetix 5500 Systems

These tables indicate the zoning requirements of cables connecting to the
Kinetix 5500 drive components.

Table 15 - Kinetix 5500 Drive

Table 16 - Capacitor Module

Wire/Cable

Connector

Zone

Method

Very
Dirty

Dirty

Clean

Ferrite
Sleeve

Shielded
Cable

L1, L2, L3 (shielded cable)

IPD

X

X

L1, L2, L3 (unshielded cable)

X

DC-/DC+ (DC bus)

DC

Bus-bar only, no wiring connector.

DC+/SH (shunt)

RC

X

U, V, W (motor power)
Motor feedback

(1)

Motor brake

MP
MF
BC

X
X
X

X
X
X

24V DC

CP

X

Safety enable for safe torque-off

(2)

STO

X

Registration input, greater than 30 m (98.4 ft)

IOD

X

X

Registration input, less than 30 m (98.4 ft)

X

Ethernet

PORT1
PORT2

X

X

(1) When the 2198-H2DCK converter kit is used, the feedback cable routes in the clean wireway.
(2) STO connector applies to only 2198-Hxxx-ERS (hardwired) servo drives.

Wire/Cable

Connector

Zone

Method

Very
Dirty

Dirty

Clean

Ferrite
Sleeve

Shielded
Cable

DC-/DC+ (DC bus)

DC

Bus-bar only, no wiring connector.

24V DC

CP

Bus-bar only, no wiring connector.

Module status

MS

X

Advertising