Noise Reduction Guidelines for Drive Accessories

Refer to this section when mounting an AC (EMC) line filter or external shunt
resistor for guidelines designed to reduce system failures caused by excessive
electrical noise.

AC Line Filters

Observe these guidelines when mounting your AC (EMC) line filter (refer to the
figure on

page 39

for an example):

Mount the AC line filter on the same panel as the Kinetix 5500 drive and

as close to the power rail as possible.

Good HF bonding to the panel is critical. For painted panels, refer to the

examples on

page 37

.

Segregate input and output wiring as far as possible.

IMPORTANT

CE test certification applies to only the AC line filter used with a single drive or
the line filter used in multi-axis drive configurations. Sharing a line filter with
more than one multi-axis drive configuration can perform satisfactorily, but
the customer takes legal responsibility.