Ch 8 - removing and replacing servo drives, Before you begin, Chapter 8 – Rockwell Automation 2198-Hxxx Kinetix 5500 Servo Drives User Manual User Manual

Page 153: Removing and replacing servo drives, Chapter

Advertising
background image

Rockwell Automation Publication 2198-UM001D-EN-P - May 2014

153

Chapter

8

Removing and Replacing Servo Drives

This chapter provides remove and replace procedures for Kinetix 5500 drives.

Before You Begin

When each drive is installed, network settings are configured from the setup
screens. Before removing the drive, revisit the Network menu and make note of
the static IP or DHCP settings. Refer to

Configure the Drive

on

page 104

to

access those settings.

You also need these tools available before you begin removal and replacement
procedures:

Screwdrivers (to loosen/remove screws)
Voltmeter (to make sure no voltage exists on drive connectors)
Non-conductive probe for removing DC bus T-connectors

Topic

Page

Before You Begin

153

Remove and Replace Kinetix 5500 Servo Drives

154

Start and Configure the Drive

156

ATTENTION: This drive contains electrostatic discharge (ESD) sensitive parts
and assemblies. You are required to follow static-control precautions when you
install, test, service, or repair this assembly. If you do not follow ESD control
procedures, components can be damaged. If you are not familiar with static
control procedures, refer to Guarding Against Electrostatic Damage, publication

8000-4.5.2

, or any other applicable ESD awareness handbook.

IMPORTANT

If you intend to use the same Logix Designer application after replacing your
drive, the new drive must be the same catalog number as the old drive.

Advertising