43

Planning the Kinetix 5500 Drive System Installation

Chapter 2

When mounting your shunt resistor inside the enclosure, follow these additional
guidelines:

Mount metal-clad modules anywhere in the dirty zone, but as close to the

Kinetix 5500 drive as possible.

Route shunt power wires with other very dirty wires.
Keep unshielded wiring as short as possible. Keep shunt wiring as flat to

the cabinet as possible.

Separate shunt power cables from other sensitive, low voltage signal cables.

Figure 18 - External Shunt Resistor Inside the Enclosure

C

C

D

D

VD

D

D

C

VD

Dirty Wireway

Clean Wireway

Single Motor Cable

Very Dirty Connections Segregated

(not in wireway)

Enclosure

No sensitive

equipment within

150 mm (6.0 in.).

Shunt Power Wiring Methods:
Twisted pair in conduit (1st choice).
Shielded twisted pair (2nd choice).
Twisted pair, two twists per foot (min) (3rd choice).

Circuit

Breaker

Digital Inputs and

Ethernet Cables

Route single motor cables
in shielded cable.

Route registration and communication

signals in shielded cables.

Kinetix 5500 Servo Drive System

24V DC

Power Supply

AC Line Filter

(required for CE)

Module Status

150 mm (6.0 in.)

clearance (min) on all four

sides of the shunt resistor.

Safety Cable

(2198-Hxxx-ERS drives only)