Rockwell Automation Publication 2198-UM001D-EN-P - May 2014

183

Kinetix 5500 Safe Torque-off - Integrated Safety

Chapter 10

When you issue a motion direct command to an axis to produce torque in
Program mode, for example MSO or MDS, with the safety connection present to
the drive, a warning message is presented before the motion direct command is
executed, as shown in

Figure 77

.

Figure 77 - STO Bypass Prompt When the Safety Controller is in Program Mode

The warning in

Figure 77

is displayed the first time a motion direct command is

issued.

After you acknowledge the warning message by clicking Yes, torque is permitted
by the drive and a warning message is indicated in the software as shown in

Figure 78

. Safety state = Not Running (torque permitted), Axis state = Stopped/

Running, Persistent Warning = Safe Torque Off Bypassed.

Figure 78 - Safety State Indications After Controller Transitions to Program Mode
(MDC executing)

IMPORTANT

Switch the controller to Run mode to exit Motion Direct Command mode
with STO function bypassed.