Configure induction motor axis properties – Rockwell Automation 2198-Hxxx Kinetix 5500 Servo Drives User Manual User Manual

Page 127

Advertising
background image

Rockwell Automation Publication 2198-UM001D-EN-P - May 2014

127

Configure and Start the Kinetix 5500 Drive System

Chapter 6

Configure Induction Motor Axis Properties

The Kinetix 5500 servo drives support basic volts/hertz and sensorless vector
frequency control methods. For more information regarding frequency control
methods, refer to

Induction Motor Control Methods

on

page 223

.

Follow these steps to configure induction motor axis properties.

1. In the Controller Organizer, right-click an axis and choose Properties.
2. Select the General category.

The General and Associated Module dialog box appears.

3. From the Axis Configuration pull-down menu, choose Frequency

Control.

4. From the Module pull-down menu, choose the drive to associate with your

Frequency Control axis.

The Module Type and Power Structure fields populate with the chosen
drive catalog number.

5. Click Apply.
6. Select the Motor category.