Certification, Important safety considerations, Chapter 9 – Rockwell Automation 2198-Hxxx Kinetix 5500 Servo Drives User Manual User Manual

Page 157: Kinetix 5500 safe torque-off - hardwired safety, For t, For i, Chapter

Advertising
background image

Rockwell Automation Publication 2198-UM001D-EN-P - May 2014

157

Chapter

9

Kinetix 5500 Safe Torque-off - Hardwired Safety

This chapter introduces you to how the hardwired safe torque-off feature meets
the requirements of Performance Level d (PLd), Category 3 according to
EN ISO 13849, and SIL CL2 according to IEC 61508, EN 61800-5-2, and
EN 62061.

The 2198-H

xxx-ERS servo drives use the safe torque-off (STO) connector for

cascading hardwired safety connections from drive-to-drive.

Certification

The TÜV Rheinland group has approved the 2198-H

xxx-ERS servo drives with

hardwired safe torque-off for use in safety-related applications up to PLd,
Category 3 according to EN ISO 13849 and SIL CL2 according to IEC 61508,
EN 61800-5-2, and EN 62061, in which removing the motion producing power
is considered to be the safe state.

Refer to Appendix E on

page 229

for these certification documents.

EC Type - Examination Certificate
EC Declaration of Conformity
European Union Directives

Important Safety Considerations

The system user is responsible for the following:

Validation of any sensors or actuators connected to the system
Completing a machine-level risk assessment
Certification of the machine to the desired EN ISO 13849 performance

level or EN 62061 SIL level

Project management and proof testing

Topic

Page

Certification

157

Description of Operation

158

Probability of Dangerous Failure Per Hour (PFH)

161

Safe Torque-off Connector Data

162

Wire the Safe Torque-off Circuit

162

Safe Torque-off Feature

164

Safe Torque-off Specifications

165

Advertising