Typical communication configurations, Linear topology – Rockwell Automation 2198-Hxxx Kinetix 5500 Servo Drives User Manual User Manual

Page 20

Advertising
background image

20

Rockwell Automation Publication 2198-UM001D-EN-P - May 2014

Chapter 1

Start

Typical Communication
Configurations

The Kinetix 5500 drives support any Ethernet topology including linear, ring,
and star.

These examples feature the CompactLogix 5370 programmable automation
controllers (catalog number 1769-L36ERM) with support for Integrated Motion
over the EtherNet/IP network. Controller features include the following:

Supports up to 16 axes
Supports up to 48 devices in linear configurations
Dual-port connectivity to support device-level ring (DLR) topology

Refer to CompactLogix Controllers Specifications Technical Data, publication

1769-TD005

, for more information on CompactLogix 5370 L1, L2, and L3

controllers.

Linear Topology

In this example, all devices are connected in linear topology. The Kinetix 5500
drives include dual-port connectivity, however, if any device becomes
disconnected, all devices downstream of that device lose communication. Devices
without dual ports must include the 1783-ETAP module or be connected at the
end of the line.

Figure 6 - Kinetix 5500 Linear Communication Installation

1 (Front)
2 (Rear)

00:00:BC:2E:69:F6

0 2

0

1734-AENTR

Module

Status
Network

Activity
Network

Status
Point Bus

Status

System

Power

Field

Power

POINT I O

Link 1

Activity/

Status

Link 2

Activity/

Status

CompactLogix 5370 Controller

Logix Designer

Application

1585J-M8CBJM-x
Ethernet (shielded) Cable

1734-AENTR POINT I/O™

EtherNet/IP Adapter

CompactLogix Controller Programming Network

PanelView™ Plus

Display Terminal

1585J-M8CBJM-OM3
0.3 m (1.0 ft) Ethernet cable
for drive-to-drive connections.

Kinetix 5500 Servo Drive System

Advertising