Power sharing sizing examples, Shared dc example – Rockwell Automation 2198-Hxxx Kinetix 5500 Servo Drives User Manual User Manual

Page 218

Advertising
background image

218

Rockwell Automation Publication 2198-UM001D-EN-P - May 2014

Appendix C

Sizing Multi-axis Shared-bus Configurations

Power Sharing Sizing
Examples

For best results, size motors based on load torque requirements by using Motion
Analyzer software. Select drives based on continuous or peak torque
requirements. Based on the load profile, use Motion Analyzer software to
estimate the net converter and inverter power and bus regulator capacity.

Table 88 - Converter and Bus Regulator Capacity

Shared DC Example

In this example four 2198-H040-ERS drives are used in a common-bus
configuration.

Figure 103 - DC Common Bus Configuration

Each 2198-H040-ERS drive is rated at 8.4 kW continuous output power to bus.
However, only the leader drive acts as the converter, so the available converter
power to the system is 8.4 kW. In this example, total motoring load must not
exceed 8.4 kW.

Configuration

Available Converter Capacity

Available Regenerative Capacity

Shared AC

Converter power rating of each drive

Internal shunt of each drive

Common bus

Converter power rating of leader drive

Sum of all internal shunts from each drive in
bus-sharing group

Shared AC/DC

Sum of converter power ratings times 0.7
(70%)

Shared AC/DC hybrid

Bonded Cabinet
Ground

Three-phase

Input Power

24V Input

Control Power

2198-H040-ERS

Common-bus Leader Drive

2198-H040-ERS

Common-bus

Follower Drives

DC Bus Connections

Advertising