Start and configure the drive – Rockwell Automation 2198-Hxxx Kinetix 5500 Servo Drives User Manual User Manual

Page 156

Advertising
background image

156

Rockwell Automation Publication 2198-UM001D-EN-P - May 2014

Chapter 8

Removing and Replacing Servo Drives

Start and Configure the Drive

Follow these steps to configure the replacement drive.

1. Reapply power to the drive/system.

Refer to

Apply Power to the Kinetix 5500 Drive

on

page 129

for the

procedure.

2. Configure the network settings for the drive.

a. If your old drive was configured as Static IP, you need to set the IP

address, gateway, and subnet mask in the new drive identical to the old
drive.
Refer to

Configure the Drive

on

page 104

to access those settings.

b. If you replaced a 2198-H

xxx-ERS2 servo drive in an integrated safety

application, review

Understanding Integrated Safety Drive

Replacement

on

page 174

and follow the appropriate procedure in

Replacing an Integrated Safety Drive in a GuardLogix System

on

page 175

to properly set the safety network number for the new drive.

3. Download the Logix Designer application to the controller.
4. Verify the drive/system is working properly.

IMPORTANT

If you intend to use the same Logix Designer application after replacing your
drive, the new drive must be the same catalog number as the old drive.