Motor feedback connections – Rockwell Automation 2198-Hxxx Kinetix 5500 Servo Drives User Manual User Manual

Page 83

Advertising
background image

Rockwell Automation Publication 2198-UM001D-EN-P - May 2014

83

Connecting the Kinetix 5500 Drive System

Chapter 5

Motor Feedback Connections

Single motor cable feedback connections are made by using the
2198-KITCON-DSL feedback connector kit.

Figure 48 - MF Connector Wiring

Table 40 - Motor Feedback (MF) Connector Specifications

IMPORTANT

When using the 2198-KITCON-DSL feedback connector kit, the ambient
temperature for the Kinetix 5500 drive enclosure is 0…50 °C (32…122 °F).

Motor Cable

Shield Clamp

Motor Feedback

Connector Kit

2198-KITCON-DSL

Feedback Connector Kit

Connector

Housing

Refer to Kinetix 5500 Feedback Connector

Kit Installation Instructions, publication

2198-IN002

, for connector kit specifications.

Internal

Grounding Plate

Clamp Screws (2)

Mounting Screws (2)

Exposed Shield

Feedback Cable
(EPWR+, EPWR-)

Cover

Kinetix 5500 Servo Drive
(front view)

2090-CSxM1DF-18AAxx

Motor Cable

IMPORTANT

Cable preparation and positioning that provides a high-frequency bond
between the shield braid and grounding plate is required to optimize
system performance.

Drive Cat. No.

Pin

Signal/
Wire Color

Wire Size
AWG

Strip Length
mm (in.)

Torque Value
N•m (lb•in)

2198-Hxxx-ERSx

MF-1

D+/Blue

22

10.0 (0.39)

0.4 (3.5)

MF-2

D-/White/Blue

IMPORTANT

The feedback bundle in 2090-CSxM1DF-18AAxx motor cables (typically used
with frame 1 drives) route around the shield clamp (as shown in

Figure 48

).

The feedback bundle in 14 and 10 AWG cables (typically used with frame 2
and 3 drives) route with the power and brake wires inside the cable shield.

Advertising