Summary of Changes

This manual contains new and updated information.

Topic

Page

Replaced catalog number string 2198-Hxxx-ERS with 2198-Hxxx-ERSx when there’s no need to
distinguish between -ERS or -ERS2.

Throughout

Added footnotes and other text to note that STO connector does not apply to 2198-Hxxx-ERS2 drives.

Added references to the Hiperface-to-DSL (series B) feedback converter kit as needed.

Added Kinetix VP (Bulletin VPF) food-grade motors.

Added LDAT-Series integrated linear thrusters.

Added 2198-Hxxx-ERS2 catalog numbers to front cover.

Front Cover

Added 2198-Hxxx-ERS2 and GuardLogix safety controller catalog numbers/descriptions to the
System Overview table.

14

Removed Safety Device from Typical Hardware Configurations.

15…19

Added Safe Torque-off Configurations.

23…25

Added 2198-Hxxx-ERS2 catalog numbers to Catalog Number Explanation.

26

Corrected the short-circuit current rating from 150,000 to 200,000 A.

31

Updated Kinetix 5500 Drive Features and Indicators with 2198-Hxxx-ERS2 drive example.

58

Updated the Absolute Position Feature section with multi-turn catalog number strings for
compatible motors and actuators.

65

Updated Safe Torque-off Safety Features with 2198-Hxxx-ERS2 drive description.

66

Updated Ethernet Cable Connections with ControlLogix EtherNet/IP communication modules.

97

Updated controller configuration by adding GuardLogix controller and ControlLogix EtherNet/IP
communication module configuration.

105

Broke out Configure the Kinetix 5500 Drive with separate procedures for 2198-Hxxx-ERS and
2198-Hxxx-ERS2 servo drives.

110 and 112

Updated Tune the Axes with a reference to the load observer feature.

133

Added FLT-S04 - MTR OVERSPEED UL fault code.
Added FLT S09 – MTR PHASE LOSS fault code.
Added FLT S49 – BRAKE SLIP FLT fault code.

141

Added FLT-M28 - SAFETY COMM fault code.

143

Added INIT FLT-M14 - SAFETY FIRMWARE fault code.

144

Updated NODE FLT fault codes.
Added NODE FLT 03 – HARDWARE 04 fault code.

144

Added NODE ALARM 04 – CLOCK SKEW ALARM.

145

Updated the configurable stopping action definitions.

149

Added FLT-S04 - MTR OVERSPEED UL fault behavior.
Added FLT S15 – CONV OVERCURRENT fault behavior.
Added FLT S49 – BRAKE SLIP FLT fault behavior.

150

Added FLT-M28 - SAFETY COMM fault behavior.

151

Added NODE FLT 05 – CLOCK SKEW FLT fault behavior

152

Updated Start and Configure the Drive with step to review an integrated safety configuration after
replacing an integrated safety drive.

156

Updated Chapter 9 title by adding Hardwired Safety to distinguish it from Chapter 10.

157

Updated System Operation timing diagram with 100 ms.

159

Updated 2198-Hxxx-ERS troubleshooting table with fault code.

159

Added Chapter 10, Kinetix 5500 Safe Torque-off - Integrated Safety.

167