Kinetix 5500 Safe Torque-off - Integrated Safety

This chapter introduces you to how the integrated safe torque-off feature meets
the requirements of Performance Level e (PLe), Category 3 according to
EN ISO 13849, and SIL CL3 according to IEC 61508, EN 61800-5-2, and
EN 62061.

With integrated safety, the 1756-L7

xS GuardLogix safety controller issues the

safe torque-off (STO) command over the EtherNet/IP network and the
2198-H

xxx-ERS2 servo drive executes the STO command.

Certification

The TÜV Rheinland group has approved the 2198-H

xxx-ERS2 servo drives

with integrated safe torque-off for use in safety-related applications up to PLe,
Category 3 according to EN ISO 13849 and SIL CL3 according to IEC 61508,
EN 61800-5-2, and EN 62061, in which removing the motion producing power
is considered to be the safe state.

Refer to Appendix E on

page 229

for these certification documents.

EC Type - Examination Certificate
EC Declaration of Conformity
European Union Directives

Topic

Page

Certification

167

Description of Operation

169

Probability of Dangerous Failure Per Hour (PFH)

171

Safe Torque-off Feature

172

Out-of-Box State

172

Understanding Integrated Safety Drive Replacement

174

Replacing an Integrated Safety Drive in a GuardLogix System

175

Motion Direct Commands in Motion Control Systems

181

Safe Torque-off Specifications

187

Safe Torque-off Specifications

187