Shared ac configurations – Rockwell Automation 2198-Hxxx Kinetix 5500 Servo Drives User Manual User Manual

Page 16

Advertising
background image

16

Rockwell Automation Publication 2198-UM001D-EN-P - May 2014

Chapter 1

Start

Shared AC Configurations

In this example, three-phase AC power and 24V control power is shared in a
multi-axis configuration. All drives must have the same power rating (catalog
number).

Figure 2 - Typical Shared AC Installations

(1) Requires the 2198-H2DCK Hiperface-to-DSL feedback converter kit. LDAT-Series linear thrusters and MP-Series (200V-class) motors

and actuators require the 2198-H2DCK (series B or later) converter kit.

1606-XL

Po we r S u p p l y

Input

Allen-Bradley

Kinetix 5500 Servo Drives (top view)

(2198-H008-ERS drives shown)

2097-Rx
Shunt Resistor
(optional component)

Line

Disconnect

Device

Input

Fusing

Three-phase

Input Power

AC Input Power

Bonded Cabinet
Ground Bus

Kinetix 5500 Servo Drives (front view)

(2198-H008-ERS drives shown)

Induction
Rotary Motors

2198-DBxx-F
AC Line Filter

(required for CE)

Bulletin 2090

Single Motor Cables

Shared AC (mains AC input)

Shared 24V (control power input)

Shared-bus connection system
for bus-sharing configurations.

Digital Inputs

to Sensors and Control String

1606-XLxxx

24V DC Control, Digital Inputs,

and Motor Brake Power

(customer-supplied)

MP-Series (Bulletin MPAS, MPAR, MPAI) Linear Actuators

(1)

MPAS-B9xxx (ballscrew) Linear Stage is Shown

MP-Series (Bulletin MPL, MPM, MPF, MPS) Rotary Motors

(1)

(MPL-Bxxxx rotary motor is shown)

2198-KITCON-DSL (shown)

Motor Feedback Connector Kit

or 2198-H2DCK Hiperface-to-DSL

Feedback Converter Kit

Kinetix VP (Bulletin VPL, VPF,

and VPS) Rotary Motors

(VPL-Bxxxx motor is shown)

LDAT-Series Linear Thrusters

(1)

(LDAT-Sxxxxxx-xDx linear thruster is shown)

IMPORTANT

In shared AC configurations, all drives must have the same power rating.

Shared AC configurations do not support Bulletin 2198 capacitor modules.

Advertising