Shared DC Common-bus Configurations

In this multi-axis example, the common-bus leader (sourcing) drive receives
three-phase AC input power and supplies DC power to common-bus follower
(sinking) drives. The common-bus leader drive power rating is greater than or
equal to the power rating of each follower drive.

Figure 4 - Typical Shared DC Common-bus Installations

(1) Requires the 2198-H2DCK Hiperface-to-DSL feedback converter kit. LDAT-Series linear thrusters and MP-Series (200V-class) motors

and actuators require the 2198-H2DCK (series B or later) converter kit.

1606-XL

Po we r S u p p l y

Input

Allen-Bradley

Kinetix 5500 Servo Drive System (top view)

2097-Rx
Shunt Resistor
(optional component)

Line

Disconnect

Device

Input

Fusing

Three-phase

Input Power

2198-H040-ERS

Common-bus Leader Drive

AC Input Power

Bonded Cabinet
Ground Bus

Kinetix 5500 Servo Drive System (front view)

2198-H008-ERS

Common-bus

Follower Drives

2198-DBxx-F
AC Line Filter

(required for CE)

Bulletin 2090 Single Motor Cables

Shared DC (DC common bus)
Shared 24V (control power input)

2198-CAPMOD-1300 Capacitor Module
(optional component)

Shared-bus connection system
for bus-sharing configurations.

Digital Inputs

to Sensors and Control String

1606-XLxxx

24V DC Control, Digital Inputs,

and Motor Brake Power

(customer-supplied)

2198-KITCON-DSL (shown)

Motor Feedback Connector Kit

or 2198-H2DCK Hiperface-to-DSL

Feedback Converter Kit

MP-Series (Bulletin MPAS, MPAR, MPAI) Linear Actuators

(1)

MPAS-B9xxx (ballscrew) Linear Stage is Shown

MP-Series (Bulletin MPL, MPM, MPF, MPS) Rotary Motors

(1)

(MPL-Bxxxx rotary motor is shown)

Kinetix VP (Bulletin VPL, VPF,

and VPS) Rotary Motors

(VPL-Bxxxx motor is shown)

LDAT-Series Linear Thrusters

(1)

(LDAT-Sxxxxxx-xDx linear thruster is shown)

IMPORTANT

In shared DC common-bus configurations, the leader drive power rating must
be greater than or equal to the power rating of the follower drives.