• tlv: enables traces for DCBX TLVs.

Defaults

none

Command
Modes

EXEC Privilege

Command
History

Version 9.4(0.0)

Supported on the FN I/O aggregator. This command is
supported in Programmable-Mux (PMUX) mode only.

fcoe-map

Create an FCoE map which contains the parameters used to configure the links between server CNAs

and a SAN fabric. Apply the FCoE map on a server-facing Ethernet port.

Syntax

fcoe-map map-name

Parameters

map-name

Maximum: 32 alphanumeric characters.

Defaults

On the FN2210S Aggregator with PMUX modules, the following parameters are
applied on all the PMUX module interfaces:

• Description: SAN_FABRIC
• Fabric-id: 1002
• Fcoe-vlan: 1002
• Fc-map: 0x0efc00
• Fcf-priority: 128
• Fka-adv-period: 8000mSec
• Keepalive: enable
• Vlan priority: 3

Command
Modes

CONFIGURATION
INTERFACE

Command
History

Version 9.6(0.0)

Supported on the FN2210S Aggregator with the PMUX
module.

Version 9.3(0.0)

Introduced on the M I/O Aggregator with the PMUX module.

Usage
Information

An FCoE map is a template used to map FCoE and FC parameters in a converged
fabric. An FCoE map is used to virtualize upstream FC ports on an FN2210S
Aggregator with the PMUX module NPIV proxy gateway so that they appear to
downstream server CNA ports as FCoE forwarder (FCF) ports on an FCoE network.
When applied to FC and Ethernet ports on an NPIV proxy gateway, an FCoE map
allows the switch to operate as an FCoE-FC bridge between an FC SAN and an