Dell PowerEdge FX2/FX2s User Manual

Page 420

Advertising
background image

Example

Dell#show system brief

Stack MAC : 00:1e:c9:f1:00:9b

-- Stack Info --

Unit UnitType Status ReqTyp CurTyp

Version Ports

---------------------------------------------------------------

------------------

---

0 Management online I/O-Aggregator I/O-

Aggregator 8-3-17-46 56

1 Standby online I/O-Aggregator I/O-

Aggregator 8-3-17-46 56

2 Member not present

3 Member not present

4 Member not present

5 Member not present

Dell#

Dell#reset stack-unit 0 >>>Resetting master not allowed

% Error: Reset of master unit is not allowed.

Dell#

Dell#reset stack-unit 1

Dell#01:02:00: %STKUNIT0-M:CP %CHMGR-5-STACKUNIT_RESET: Stack

unit 1 being reset

01:02:00: %STKUNIT0-M:CP %IFMGR-1-DEL_PORT: Removed port: Te

1/1-32,41-56

01:02:00: %STKUNIT0-M:CP %CHMGR-2-STACKUNIT_DOWN: Stack unit 1

down - reset

01:02:00: %STKUNIT1-S:CP %IFMGR-1-DEL_PORT: Removed port: Te

1/1-32,41-56

01:02:05: %I/O-Aggregator:0 %IFAGT-5-STACK_PORT_LINK_DOWN:

Changed stack port

state to down: 0/10

01:02:11: %STKUNIT0-M:CP %POLLMGR-2-ALT_STACK_UNIT_STATE:

Alternate Stack-unit is

not present

Dell#01:02:12: %STKUNIT0-M:CP %CHMGR-2-STACKUNIT_DOWN: Stack

unit 1 down - card

removed

Related
Commands

reload

— reboots the system.

power-cycle stack-unit

— resets the designated stack member.

show system stack-ports

Display information about the stacking ports on all switches in the FN I/O Aggregator switch stack..

Syntax

show system stack-ports [status | topology]

Parameters

status

(OPTIONAL) Enter the keyword status to display the
command output without the Connection field.

topology

(OPTIONAL) Enter the keyword topology to limit the table
to just the Interface and Connection fields.

Defaults

none

420

Advertising