Dell PowerEdge FX2/FX2s User Manual

Page 355

Advertising
background image

• Forced-master
• Force-slave
• Master
• Slave
• Auto-neg Error — typically indicates that both ends of the node are configured

with forced-master or forced-slave.

CAUTION: Ensure that one end of your node is configured as forced-master
and one is configured as forced-slave. If both are configured the same (that
is, forced-master or forced-slave), the show interfaces command flaps
between an auto-neg-error and forced-master/slave states.

You can display master/slave settings with the show interfaces command.

Example
(Master/Slave)

Dell(conf)# int tengig 0/1

Dell(conf-if)#neg auto

Dell(conf-if-autoneg)# ?

end Exit from configuration mode

exit Exit from autoneg configuration mode

mode Specify autoneg mode

no Negate a command or set its defaults

show Show autoneg configuration information

Dell(conf-if-autoneg)#mode ?

forced-master Force port to master mode

forced-slave Force port to slave mode

Dell(conf-if-autoneg)#

Example
(Master/Slave,
partial)

Dell#show interfaces configured

TenGigabitEthernet 0/1 is up, line protocol is up

Hardware is DellEth, address is 00:1e:c9:de:04:9c

Current address is 00:1e:c9:de:04:9c

Server Port AdminState is N/A

Pluggable media not present

Interface index is 33886978

Internet address is not set

Mode of IPv4 Address Assignment : NONE

DHCP Client-ID :001ec9de049c

MTU 12000 bytes, IP MTU 11982 bytes

LineSpeed 10000 Mbit

Flowcontrol rx on tx off

ARP type: ARPA, ARP Timeout 04:00:00

Last clearing of "show interface" counters 03:56:48

Queueing strategy: fifo

Input Statistics:

...

User
Information

Both sides of the link must have auto-negotiation enabled or disabled for the link
to come up.

The following details the possible speed and auto-negotiation combinations for a
line between two 10/100/1000 Base-T Ethernet interfaces.

Port 0

• auto-negotiation enabled* speed 1000 or auto

355

Advertising