Dell PowerEdge FX2/FX2s User Manual

Page 419

Advertising
background image

show system stack-ports

show system stack-unit stack-group

stack-unit iom-mode

power-cycle stack-unit

To hard reset any stack unit including master unit.

Syntax

power-cycle stack-unit unit-number

Parameter

Unit number

The unit number ranges from 0 to 5.

Defaults

None

Command
Modes

EXEC Privilege

Command
History

Version 9.6.
(0.0)

Supported on the FN I/O Aggregator.

Usage
Information

This command is supported on the FN410S and the FN410T Aggregators.

This command is used to reset the stack-unit. The master unit can also be power
cycled using this command.

reset stack-unit

Reset any designated stack member except the management unit (master unit).

Syntax

reset stack-unit 0–5 hard

Parameters

0–5

Enter the stack member unit identifier of the stack member
to reset.

hard

Reset the stack unit if the unit is in a problem state.

Defaults

none

Command
Modes

EXEC Privilege

Command
History

Version 9.6.
(0.0)

Supported on the FN I/O Aggregator.

Usage
Information

This command is supported on the FN410S and the FN410T Aggregators

Resetting the management unit is not allowed and an error message displays if you
try to do so. Resetting is a soft reboot, including flushing the forwarding tables.

You can run this command directly on the stack standby unit (Standby Master) to
reset the standby. You cannot reset any other unit from the standby unit

419