NOTE: The :: notation specifies successive hexadecimal
fields of zeros.

hostname

Enter the name of a host already configured and recognized
by the switch.

Defaults

Disabled.

Command
Modes

CONFIGURATION

Command
History

Version 9.4(0.0)

Supported on the FN I/O aggregator. This command is
supported in Programmable-Mux (PMUX) mode only.

Usage
Information

Multiple logging servers of both IPv4 and/or IPv6 can be configured.

logging buffered

Enable logging and specify which messages are logged to an internal buffer. By default, all messages are

logged to the internal buffer.

Syntax

logging buffered [level] [size]
To return to the default values, use the default logging buffered command.

To disable logging stored to an internal buffer, use the no logging buffered
command.

Parameters

level

(OPTIONAL) Indicate a value from 0 to 7 or enter one of the
following equivalent words: emergencies, alerts,
critical, errors, warnings, notifications,
informational, or debugging. The default is 7 or
debugging.

size

(OPTIONAL) Indicate the size, in bytes, of the logging buffer.
The number of messages buffered depends on the size of
each message. The range is from 40960 to 524288. The
default is 40960 bytes.

Defaults

level = 7; size = 40960 bytes

Command
Modes

CONFIGURATION

Command
History

Version 9.4(0.0)

Supported on the FN I/O aggregator. This command is
supported in Programmable-Mux (PMUX) mode only.

Usage
Information

When you decrease the buffer size, all messages stored in the buffer are lost.
Increasing the buffer size does not affect messages stored in the buffer.