fc-map-value

Enter the unique MAC address prefix used by a SAN fabric.
The range of FC-MAP values is from 0EFC00 to 0EFCFF.

Defaults

None

Command
Modes

FCoE MAP

Command
History

Version 9.6(0.0)

Supported on the FN 2210S Aggregator.

Version 9.3(0.0)

Introduced on the M I/O Aggregator and MXL 10/40GbE
Switch with the FC Flex IO module.

Usage
Information

The FC-MAP value you enter must match the FC-MAP value used by an FC switch
or FCoE forwarder (FCF) in the fabric. An FCF switch accepts only FCoE traffic that
uses the correct FC-MAP value.

The FC-MAP value is used to generate the fabric-provided MAC address (FP-MAC).
The FPMA is used by servers to transmit FCoE traffic to the fabric. An FC-MAP can
be associated with only one FCoE VLAN and vice versa.

In an FCoE map, the FC-MAP value, fabric ID, and FCoE VLAN parameters must be
unique.

To remove a configured FC-MAP value from an FCoE map, enter the no fc-map
command.

Related
Commands

fcoe-map

— creates an FCoE map which contains the parameters used in the

communication between servers and a SAN fabric.

show fcoe-map

— displays the Fibre Channel and FCoE configuration parameters in

FCoE maps.

fcoe-map

Create an FCoE map which contains the parameters used to configure the links between server CNAs

and a SAN fabric. Apply the FCoE map on a server-facing Ethernet port.

Syntax

fcoe-map map-name

Parameters

map-name

Maximum: 32 alphanumeric characters.

Defaults

On the FN2210S Aggregator with PMUX modules, the following parameters are
applied on all the PMUX module interfaces:

• Description: SAN_FABRIC
• Fabric-id: 1002
• Fcoe-vlan: 1002