Reset and clocks – Altera Stratix V Avalon-ST User Manual

Page 107

Advertising
background image

Reset and Clocks

6

2014.12.15

UG-01097_sriov

Subscribe

Send Feedback

Stratix V Hard IP for PCI Express IP Core includes both a soft reset controller and a hard reset controller.

Software selects the appropriate reset controller depending on the configuration you specify. Both reset

controllers reset the IP core and provide sample reset logic in the example design. The figure below

provides a simplified view of the logic that implements both reset controllers.

Table 6-1: Use of Hard and Soft Reset Controllers

Reset Controller Used

Description

Hard Reset Controller

pin_perst

from the input pin of the FPGA resets the Hard IP for PCI Express

IP Core.

app_rstn

which resets the Application Layer logic is derived from

reset_status

and

pld_clk_inuse

, which are outputs of the core. This reset

controller is supported for Gen 1 production devices.

Soft Reset Controller

Either

pin_perst

from the input pin of the FPGA or

npor

which is derived

from

pin_perst

or

local_rstn

can reset the Hard IP for PCI Express IP

Core. Application Layer logic generates the optional

local_rstn

signal.

app_

rstn

which resets the Application Layer logic is derived from

npor

.

This reset controller is supported for Gen2 and Gen3 production devices.

©

2014 Altera Corporation. All rights reserved. ALTERA, ARRIA, CYCLONE, ENPIRION, MAX, MEGACORE, NIOS, QUARTUS and STRATIX words and logos are

trademarks of Altera Corporation and registered in the U.S. Patent and Trademark Office and in other countries. All other words and logos identified as

trademarks or service marks are the property of their respective holders as described at

www.altera.com/common/legal.html

. Altera warrants performance

of its semiconductor products to current specifications in accordance with Altera's standard warranty, but reserves the right to make changes to any

products and services at any time without notice. Altera assumes no responsibility or liability arising out of the application or use of any information,

product, or service described herein except as expressly agreed to in writing by Altera. Altera customers are advised to obtain the latest version of device

specifications before relying on any published information and before placing orders for products or services.

ISO

9001:2008

Registered

www.altera.com

101 Innovation Drive, San Jose, CA 95134

Advertising