For descriptions of the available reset signals, refer to Reset Signals, Status, and Link Training Signals.

Function Level Reset (FLR)

The following sequence of events occurs after a FLR to a Physical Function:
1. The host stops all traffic from and to the Function.

2. The host writes the FLR bit in the

Device Control

Register to trigger the FLR reset.

3. The SR-IOV Bridge resets R/W non-sticky control bits in the Configuration Space of the Function. It

notifies the Application Layer via

flr_active_*

signals.

4. The Application Layer cleans up all state related to the Function. It asserts FLR Completed via

flr_completed_*

signal. The Application Layer should either discard all pending requests from the

Function, or send Completions. If the Application Layer sends Completions, the host drops them

without checking for errors.

5. The SR-IOV Bridge re-enables the Function by deasserting the

flr_active_*

signal associated with

this function.

6. The host re-enumerates the Function.

This handshake ensures that the Completion for a request issued before the FLR does not return

after the FLR is complete.

Related Information

Function-Level Reset Interface

on page 4-13

Clocks

The Hard IP contains a clock domain crossing (CDC) synchronizer at the interface between the

PHY/MAC and the DLL layers. The synchronizer allows the Data Link and Transaction Layers to run at

frequencies independent of the PHY/MAC. The CDC synchronizer provides more flexibility for the user

clock interface. Depending on parameters you specify, the core selects the appropriate

coreclkout_hip

.

You can use these parameters to enhance performance by running at a higher frequency for latency

optimization or at a lower frequency to save power.
In accordance with the PCI Express Base Specification, you must provide a 100 MHz reference clock that is

connected directly to the transceiver.
As a convenience, you may also use a 125 MHz input reference clock as input to the TX PLL.

Related Information

PCI Express Base Specification 2.1 or 3.0

Clock Domains

UG-01097_sriov

2014.12.15

Function Level Reset (FLR)