Example:

1 - Press <Alt Gr><F4> to set the Record mode. The 5250 status line is

set in reverse video mode and the following information is displayed
(the 24 boxes are the 24 function keys, a solid box means that data is
recorded):

MEMOR 127 „……… „……… ………… ………… ………… ………… 17/21

2 - Press one of the function keys (<F1> to <F12> or <Shift><F1> to

<Shift><F12>). The 5250 status line is set in normal mode and the
following information is displayed:

R 127 F1 17/21

Note: 'R' indicates the Record mode. The second field is the maximum
keystrokes that can be recorded for this session (max. 127). The third
field is the selected function key.

3 -

Type the key sequence. Note the keystroke counter shows the
remaining keystrokes that can be recorded for this function key (max.
63). As you type this counter is decreased.

4 - To exit the Record mode, press <Alt Gr><F4>.

b) Processing a key sequence

To execute a series of keystrokes that have been recorded:

- press <Alt Gr><F5> to set the Process mode,
- press the recorded function key,
- the key sequence is processed.

Example:

1 - Press <Alt Gr><F5> to set the Process mode. The 5250 status line is

set in reverse video mode and the following information is displayed
(the 24 boxes are the 24 function keys, a solid box means that data is
recorded):

EXEC „……… „……… ………… ………… ………… ………… 17/21

2 - Press the recorded function key (<F1> to <F12> or <Shift><F1> to

<Shift><F12>). The 5250 status line is set in normal mode and the
following information is displayed (the 'P' symbol indicates the Process
mode). The key sequence is processed:

P 17/21

Note: during the process mode, the input is inhibited.