Axel AX3000 65 User's Manual User Manual

Page 204

Advertising
background image

Remote Set-Up


192

AX3000 - User's Manual

ERR 103: trailer label not found. Default factory set-up reloaded

Command:

setup_send

Cause:

the trailer label (END_AX_SETUP) is not found. (Either this
label is not included in the configuration file or the
connection failed).

Consequence: the default factory set-up is reloaded (to replace the

inconsistent configuration caused by the missing trailer
label).

Solution:

add this label to the end of file and run the command again.


ERR 104: Can not get complete set-up (rcmd command aborted).

Command:

setup_get

Cause:

a network problem has occurred or the command has been
killed or aborted.

Consequence: the set-up obtained by the command is invalid (the trailer

label is missing).

Solution:

run the command again.


ERR 105: invalid rcmd command.

Command:

---

Cause:

the keyword is unknown.

Consequence: no effect.
Solution:

use the correct keyword (setup_send, setup_get or
ax_reboot).


ERR 106: cmos busy.

Command:

setup_send

Cause:

another command (setup_get or setup_send) is running, or
another user has entered set-up on the target AX3000.

Consequence: no effect.
Solution:

Either wait for a few seconds and repeat the command, or
arrange for the other user to exit set-up on the target
AX3000.

Advertising