Axel AX3000 65 User's Manual User Manual

Page 219

Advertising
background image

Downloading

Firmware


AX3000 - User's Manual

207

11.5 - IN EVENT OF DIFFICULTIES

This section describes possible problems. The error list is not exhaustive. If an
unlisted error occurs, please contact your AXEL distributor.

After an error, the AX3000 should be power-cycled.

11.5.1 - The bootp Stage

If an error occurs, the following message is displayed on the AX3000 monitor:

Bootp errno: xxx

- xxx is the error number.

Possible errors:

0: Ethernet board not responding.
1: no response to the bootp broadcast request (the bootp host is

unreachable or not correctly set-up).

11.5.2 - The tftp Stage

A tftp error message can originate from either the tftp host or the AX3000.

Depending on the error, the AX3000 firmware may be erased. If this happens
the firmware code will be automatically downloaded (bootp+tftp protocol) the
next time the AX3000 is power-cycled.

Tftp Host Errors:

tftp errno: xxx label

- xxx is the error number,

- label is the error message. This label is sent by the tftp host and is

generated by UNIX running on the tftp host.

Possible errors:

1: File not found
2: Access violation
3: Disk full or allocation exceeded
4: Illegal TFTP operation

Advertising
This manual is related to the following products: