Media thickness adjustment – Rena T-650 User Manual

Page 19

Advertising
background image

MECHANICAL SETUP

Media Thickness Adjustment

IMPORTANT: To permit proper feeding through the tabber; the media you plan to tab/stamp
must have square, tight folds, and be nearly uniformly thick. If the media does not feed properly,
it will not be tabbed/stamped properly.


1. Close the Exit Roller Assembly [2] and lock the two latches to secure it.

2. Turn the Media Thickness Control Knob [1] fully clockwise (raising the exit roller

assembly).

3. Insert one piece of media [3] into the exit end of the tabber and adjust the Media

Thickness Control Knob [1] counter-clockwise (lowering the exit roller assembly) until
you start to feel a drag on the media.

4. Continue to turn the Media Thickness Control Knob [1] counter-clockwise an additional

3 or 4 clicks, to obtain proper transport pressure on the media.

5. If installed; loosen the thumb screw for the Hold-Down Guide, and allow the guide

(strap) to relax. Then re-secure the thumb screw.
This will prevent the guide from putting too much
pressure on the media, possibly causing it to stall.

6. Proceed to the section titled “

Adjusting the Peel

Plate Position for the Application

”.

1

3

2

T-650 Operations REV. 8/25/2010