When the automatic soft key is pressed, Press the save key to accept and save this value – Rena T-650 User Manual

Page 45

Advertising
background image

OPERATION

When the Automatic soft key is pressed.

Enter Product Length and press SAVE key
0.0” Current Value: 11.000”
Status: Head #n Automatic Setup
Automatic BACK

The display may prompt you to

“Increase

Transport Speed” or “Decrease Transport
Speed”. Adjust the transport speed until the
display shows “Feed 1 Product now”.

When the display reads “Feed 1 Product
now”; feed one of your mail pieces through
the tabber.

Note: Feeding more than one mail piece will
cause an incorrect length to be measured and set.

Feed 1 Product now
Status: Tabber is in the pass thru mode.

BACK

After the piece has fed through the tabber, the
tabber will stop and

display the piece length.

Verify the measurement!
It must be accurate (+ or - 0.250”).

Enter piece length and press SAVE key
0.00” Current Value: 8.523”
Status: Pieces: 2
Automatic

BACK

• If the tabber measures the piece to be

longer then the actual piece length;
then the media may be slipping or
hesitating as it feeds. Check/Adjust
the transport system.

• If the tabber measures the piece to be

shorter than the actual piece length; then the media may not be feeding straight
(missing the sensor), or a hole in the media may be traveling through the sensor, or
the sensor may be getting reflection off the mail piece. If using a high gloss media,
the sensor intensity may need to be adjusted lower by a qualified Rena service
person.
If the media passes through without the tabber providing a measurement; then the
media sensor may be dirty. Try cleaning the sensor as described in this manual.
These problems need to be corrected before the tabber will function correctly.

Manual Product Length Input:
As an option, you can set the piece length manually. However; doing so will not fix a tab
placement problem that is caused by a media feeding or media sensing issue.
In other words; if the Tabber’s Automatic Product Length feature is not reading the piece
length accurately than setting the product length manually is not going to fix a problem.
See “Verify the measurement” above.

If you want to manually enter the length of the media:

1. Measure the physical piece length, using the scale provided on the control panel.

2. Enter this value, in inches and tenths of an inch, using the numeric key pad.

3. Press the Save Key to accept and save this value.

4. Press the BACK key to return to the previous screen.

T-650 Operations REV. 8/25/2010