SECTION 3 - CHASSIS & TURNTABLE
3121448
– JLG Lift –
3-73
20. Remove the valve housing (66).
21. Remove the O-ring seals (67) from their seats in the
valve housing (66).
22. Remove the plugs (61) of the anticavitation valve from
the valve housing (66) previously loosened.
23. Remove the O-ring seal (62) from each plug (61).
24. By using pliers remove the nos. 2 springs (63).
25. Remove the spool (65) from the anticavitation valve
housing (66).