4 calibration instructions, Calibration procedure reasons for re-calibration – JLG X23J - X700AJ Service Manual User Manual

Page 502

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121448

– JLG Lift –

6-13

6.4 CALIBRATION INSTRUCTIONS

This machine incorporates a variety of sensors and a high
degree of function interaction. For safety and proper
machine functionality, the calibration procedures must be
repeated for any control module replacement, system cal-
ibration related fault, or removal or replacement of any
sensors, valves, coils.

The chart below lists the calibrations required and poten-
tial reasons for recalibrating.

All calibration procedures are menu driven through the
REMOTE CONTROL.

The user is prompted to exercise the machine in a specific
order to use the machines physical properties to consis-
tently establish sensor response and the interaction of
valves, pumps, and motors.

A REPLACEMENT ON A NEW ECM 1-2 REQUIRE TO FLASH THE
PROPER MACHINE MODEL SOFTWARE AND TO ADJUST THE
MACHINE SETTINGS. A REPLACEMENT OF A NEW ECM 1-2 DO
NOT REQUIRE THE CALIBRATION OF THE ECM3/ECM4 JOY-
STICKS AND RADIO CONTROL.

Table 6-2. Calibration Instructions

Calibration

Procedure

Reasons for

Re-calibration

LOAD Cell
Calibration

LSS Module ECM3

replacement

LSS Sensor removal or

replacement

Joystick Calibration

Joystick replacement

Chassis Tilt
Calibration

Master Board ECM1- ECM2

removal or replacement

Tilt indication inaccuracy

Rotator Sensors
Calibration

X700AJ X23J Only Board

ECM4 rotator sensor

replacement Rotator sensor

removal or replacement

Radio Control
Calibration

X14HJ X17J Only

Radio Control replacement

Advertising