SECTION 3 - CHASSIS & TURNTABLE

3121448

– JLG Lift –

3-247

INSPECTION

• CRANKSHAFT POSITION (CKP) SENSOR

Measure the resistance between the terminal and the
installation fitting.

• CHARGE COIL

Measure the resistance between the terminals.

• POWER COIL

1. Remove the terminal cover from the connector using

a flat-tip screwdriver.

2. Measure the resistance between the BI and G termi-

nals.

• FUEL CUT SOLENOID COIL

Measure the resistance between the terminals.

Specified resistance

216 - 264 Ω

Specified resistance

3A

1.8 - 2.8 Ω

20A

0.1 - 0.3 Ω

Specified resistance

3.5 - 5.3 Ω

Specified resistance

3.1 - 4.7 Ω