Code meaning – JLG X23J - X700AJ Service Manual User Manual

Page 530

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121448

– JLG Lift –

6-41

38

Contactor Open

Cause: The inverter feeds the relay’s coil but the contact does not close.

Solution: Control the relay and the power to the coil

49

I=0 Ever

Cause: Feedback current from motor’s sensor not constantly kept at 0

Solution: Control the connection with the motor

53

STBY I high

Cause: Fault detected in the inverter

Solution: Usually it is a temporary anomaly due to a particular working condition. In case
the anomaly persists replace the inverter.

60

Capacitor Charge

Cause: Problem in the inverter

Solution: Control the connections and the motor phases

61

High temperature

Cause: Temperature rise in the inverter.

Solution: Allow a better cooling to the inverter. If the anomaly persists contact JLG after
sales dept.

65

Motor temper at

Cause: High motor temperature

Solution: Stop the machine temporarily to enable motor cooling

67

Can Bus KO

Cause: The inverter does not receive any information from Can Bus line

Solution: Control the connections with the multi function tool

70

Encoder Error

Cause: Anomaly detected on encoder (= engine rpm sensor)

Solution: Control the rpm sensor connection. The anomaly may also be caused by a bear-
ing fault.

73

Therm is sensor KO

Cause: The signal from the temperature sensor is higher than 4,95 Volt or lower than 0,1
Volt

Solution: Usually it is a temporary anomaly due to a particular working condition. In case
the anomaly persists replace the inverter.

74

Driver shorted

Cause: Anomaly to the relay supply.

Solution: Control relay supply. Usually it is a temporary anomaly due to a particular work-
ing condition. In case the anomaly persists replace the inverter.

75

Driver shorted

Cause: Anomaly to the relay supply.

Solution: Control relay supply. Usually it is a temporary anomaly due to a particular work-
ing condition. In case the anomaly persists replace the inverter.

Table 6-6. INVERTER Diagnostic trouble code chart

CODE

MEANING

Advertising