Functions speed range – JLG X23J - X700AJ Service Manual User Manual

Page 536

Advertising
background image

SECTION 6 - JLG CONTROL SYSTEM

3121448

– JLG Lift –

6-47

Table 6-8. Time range (sec)

FUNCTIONS SPEED RANGE

FUNCTION

JOYSTICK

TIME Sec

X14J

X390AJ

TIME Sec

X19J

X550AJ

TIME Sec

X23J

X700AJ

TELESCOPE EXTEND

J4

21" - 23"

21" - 23"

45" - 65"

ENGINE RPM

3000

3600

3600

TELESCOPE RETRACT

J4

13" - 15"

16" - 18"

29" - 45"

ENGINE RPM

3000

3600

2200

TOWER BOOM UP

J2

18" - 21"

28" - 30"

50" - 60"

ENGINE RPM

3000

2200

2200

TOWER BOOM DOWN

J2

16" - 20"

27" - 29"

56" - 70"

ENGINE RPM

3000

1500

1500

UPPER BOOM UP

J3

25" - 27"

29" - 31"

48" - 57"

ENGINE RPM

3000

2200

1500

UPPER BOOM DOWN

J3

25" - 27"

31" - 33"

60" - 70"

ENGINE RPM

3000

1500

1500

BASKET ROTATE RIGTH

J5

//

7" - 9"

7" - 9"

BASKET ROTATE LEFT

J5

//

7" - 9"

7" - 9"

ENGINE RPM

3000

1500

1500

SWING LEFT

J7

1':00" - 1.06"

41" - 47"

1':20" - 1.40"

SWING RIGTH

J7

1':00" - 1.06"

41" - 47"

1':20" - 1.40"

ENGINE RPM

3000

1500

1500

JIB UP

J6

8.5" - 10"

16" - 25"

14" - 25"

JIB DOWN

J6

8.5" - 10"

11" -13"

10" - 13"

ENGINE RPM

3000

1500

1500

BASKET LEVEL UP

J9

7" - 11"

37" - 39"

37" - 39"

BASKET LEVEL DOWN

J9

10" - 13"

27" - 29"

27" - 37"

ENGINE RPM

3000

1500

1500

Drive Forward /Reverse
Low Speed m/s

J1

0.39"

0.47"

0.28"

High Speed m/s

J8

0.78"

0.92"

0.47"

Advertising