Advertising
background image

SECTION 3 - CHASSIS & TURNTABLE

3-186

– JLG Lift –

3121448

REGULATOR/RECTIFIER INSPECTION

Measure the resistance between the terminals and be
sure that the measurements conform to the ranges shown
in the table.

10A TYPE

18A TYPE

Use a tester that is equivalent to or higher than the perfor-
mance specified, internal resistance: 20 k./VDC,9 k./VAC

Be careful not to touch the metallic part of the tester probe
with your fingers; otherwise, the correct resistance value
cannot be obtained.

Read the tester manufacturer‘s operation instructions
carefully before operating the tester. Follow the instruc-
tions of the Service Manual. Be sure the tester‘s battery is
fully charged, and check the meter before using the tester.

Unit: kŸ

4

6

1

3

4

6

1

1-200

1-200

0.5-100

3

0.1-50

0.1-50

Not used

4

6

3

1

Unit: kŸ

4

6

1

2

3

4

4 - 400

2 - 230

6

4 - 400

2 - 230

1

2

2 - 230 2 - 230

1 - 600

3

0.09 -

400

0.09 -

400

Not used

4

6

3

1

2