SECTION 6 - JLG CONTROL SYSTEM

3121448

– JLG Lift –

6-51

SETUP 1 - ACCELER
(CALIBRATING TILT SENSOR)

This menu allows the calibration of the tilt sensor.

A NEW TILT MODULE WILL ACT AS IF IT IS TILTED ALL OF THE
TIME UNTIL THE FOLLOWING PROCEDURE IS PERFORMED.

CALIBRATE THE LEVEL SENSOR EXCEPT WITH THE UNITY LEV-
ELED ON BOTH AXLE. CHECK THE BUBBLE LEVEL TO CONFIRM
UNIT IS LEVEL (BUBBLE IS IN THE 1° GREEN (CENTER)
AREA).

IF THE BUBBLE IN THE LEVEL IS NOT IN THE GREEN
AREA, EXTEND THE SIDE OUTRIGGERS UNTIL UNIT
IS LEVEL (BUBBLE IS IN THE 1° GREEN (CENTER)
AREA).

Figure 6-21.

1. Engine OFF.

2. Engine Key Switch ON.

3. Press button 6 "SERVICE"

4. Press button 7 "SETUP“

5. Press button 5 “PASSWORD”

Using the remote control buttons to enter the pass-
word 2857.

NOTE: password above allow to calibrate the TILT SENSOR

.

Once the correct password is accepted the display
shown “OK”.

6. Press button 9 “ESC”.

Repeat the above steps if “NO” appear on the dis-
play.

7. Press button 1 “ACCELER” to enter in SETUP TILT

SENSOR.

8. Press Button 1 to reset the TILT.

Check the values if both axle showed in the display
become zero, otherwise press button 1 again until both
values are zero.

Press 3 times button 9 to Esc to escape.

0,2

A

3,23,2

B B

B B

APPOGGIO_POST