SECTION 3 - CHASSIS & TURNTABLE

3-242

– JLG Lift –

3121448

RECTIFIER/REGULATOR RECTIFIER

Measure the resistance between the terminals.

• Use a tester that is equivalent to or higher than the per-

formance specified:

Internal resistance: 20 Ω/VDC, 9 Ω/VAC

• Be careful not to touch the metallic part of the tester

probe with your fingers, otherwise correct resistance
value cannot be obtained.

• Read the tester manufacturer's operation instructions

carefully before operating the tester. Follow the instruc-
tions of the Service manual. Be sure the tester's battery
is fully charged and check the meter before using the
tester.

• Use the R x 1 scale of a commercially available millime-

ter that meter shows current flow from negative (-) to
positive (+). If the meter shows current flow in one
direction but not the other, the diode is goad.

FUSE

1. Check for. a blown fuse; replace if necessary.

2. If the replaced fuse blows out, check the following.

30A FUSE:

a. Check the combination switch.
b. Check the wire harness connecting the combi-

nation switch and ECM (Bl/Y) for open or short
circuit.

c. Check the rectifier or regulator rectifier.

3A FUSE:

d. Check the combination switch.
e. Check the wire harness connecting the combi-

nation swatch and ECM (BI/Y) for open or short
circuit.