SECTION 3 - CHASSIS & TURNTABLE

3-116

– JLG Lift –

3121448

1)

F

M

for hydraulic bolt-tensioning cylinder pretension ed

to 85% of yield strength.

Table 3-8.

1)

F

M

for hydraulic bolt-tensioning cylinder pretensioned

to 85% of yield strength.

DETERMINING THE TILTING CLEARANCE

Tilting clearance increases as raceway system wear
increases. To determine the increase in tilting clearance a
basic measurement must be executed in installed status
and prior to first-time operation. This is the only way to
determine changes.

Figure 3-195. Determine tilting clearance

1. Upper mounting structure

2. Tilting direction

3. Main load-carrying zone

4. Lower mounting structure

Figure 3-196. Measurement setup

5. Dial gauge

6. Upper mounting structure

Table 3-7.

Mounting

bolt dimen-

sions

Mounting pretension force

F

M

1)

Strength class 10.9 in

kN

lbs

M24

282

63396

M27

367

82505

M30

448

100714

M33

554

124544

M36

653

146800

M42

896

201429

M45

1043

234476

M48

1177

264600

M52

1405

315857

M56

1622

364640

M60

1887

424215

M64

2138

480642

M68

2441

548759

Mounting

bolt dimen-

sions

Mounting pretension force

F

M

1)

Strength class 10.9 in

kN

lbs

1 – 8 UNC

301

67668

1 1/8 – 7 UNC

379

85203

1 1/4 – 7 UNC

481

108133

1 3/8 – 6 UNC

573

128816

1 1/2 – 6 UNC

697

156692

1 5/8 – 6 UNC

832

187041

1 3/4 – 5 UNC

942

211770

Advertising