SECTION 3 - CHASSIS & TURNTABLE
3121448
– JLG Lift –
3-255
IGNITION COIL
Primary side
Measure the resistance between the GND and IGN termi-
nals.
Secondary side
Measure the resistance between the GND terminal and
the sprig in the spark plug cap.
Specified resistance
0.16-0.21 Ω
Specified resistance
3.74-4.58 kΩ