Table 6-4. Menu Input

X17J

ST1 A GND

ON

Stabiliser 1 on the ground – The switch is released and line A is closed

OFF

Stabiliser 1 raised – The switch is pressed and line A is open

ST1 B GND

ON

Stabiliser 1 on the ground – The switch is released and line B is closed

OFF

Stabiliser 1 raised – The switch is pressed and line B is open

FREE

Ignore this signal

FREE

Ignore this signal

ST2 A GND

ON

Stabiliser 2 on the ground – The switch is released and line A is closed

OFF

Stabiliser 2 raised – The switch is pressed and line A is open

ST2 B GND

ON

Stabiliser 2 on the ground – The switch is released and line B is closed

OFF

Stabiliser 2 raised – The switch is pressed and line B is open

FREE

Ignore this signal

FREE

Ignore this signal

ST3 A GND

ON

Stabiliser 3 on the ground – The switch is released and line A is closed

OFF

Stabiliser 3 raised – The switch is pressed and line A is open

ST3 B GND

ON

Stabiliser 3 on the ground – The switch is released and line B is closed

OFF

Stabiliser 3 raised – The switch is pressed and line B is open

FREE

Ignore this signal

FREE

Ignore this signal

ST4 A GND

ON

Stabiliser 4 on the ground – The switch is released and line A is closed

OFF

Stabiliser 4 raised – The switch is pressed and line A is open

ST4 B GND

ON

Stabiliser 4 on the ground – The switch is released and line B is closed

OFF

Stabiliser 4 raised – The switch is pressed and line B is open

FREE

Ignore this signal

FREE

Ignore this signal

ESSICAE A

ON

The aerial part safety devices are deactivated by the key switch (emergency
condition) – Line A of the aerial part safety bypass button is closed

OFF

The aerial part safety devices are active (normal operating condition) – Line A of
the aerial part safety bypass button is open