JLG X23J - X700AJ Service Manual User Manual

Page 437

Advertising
background image

SECTION 5 - HYDRAULICS

3121448

– JLG Lift –

5-11

MAGNETIC SENSOR REMOVING

1. Pull out retain clip with pliers.

Figure 5-20.

2. Pull out the spacer.

Figure 5-21.

3. Pull out the magnet.

Figure 5-22.

4. Pull out the other spacer.

Figure 5-23.

THREADED PISTON DISASSEMBLING

PROTECT THE FINISH ON THE ROD AT ALL TIMES. DAMAGE TO
THE SURFACE OF THE ROD CAN CAUSE SEAL FAILURE.

Fix the rod into the vice.

NOTE: Before attempting to disassemble the piston remove

any accessible seals.

Figure 5-24.

NOTE: Apply heat to break the bond of the sealant between

the piston and the rod before the piston can be
removed.

WARM THE SURFACE INDICATED MAX 300°C

Avoid overheating, or the parts may become distorted or
damaged.

Figure 5-25.

Apply sufficient torque for removal while the parts are still
hot. The sealant often leaves a white, powdery residue on
threads and other parts, which must be removed by
brushing with a soft brass wire brush prior to reassembly.

Advertising