SECTION 3 - CHASSIS & TURNTABLE

3121448

– JLG Lift –

3-179

BRUSH CONTINUITY CHECK

Check for continuity between the positive (+) brushes(1)
and negative (-) brushes (2).

There should be continuity between both the positive-
brushes.There should be continuity between both the
negativebrushes.There should be no continuity from
either positive brush to either negative brush.

If the correct continuity of the positive (+) brushes is not
obtained, replace the center bracket (page 10-9).

If the correct continuity of the negative (-) brushes is not
obtain, replace the negative (-) brushes.

ARMATURE MICA DEPTH

Visually inspect the commutator surface for dust, rust,or
other damage. If necessary, wipe it with a clean lint-free
cloth. If rusted or damaged, dress with a fine emery cloth.

When the mica is clogged, or its depth is smaller than the
service limit value, recut the grooves using a hacksaw
blade or a small file.

STANDARD:1.0 mm (0.04 in)

SERVICE LIMIT:0.2 mm (0.01 in)

ARMATURE CONTINUITY CHECK -
COMMUTATOR TO SHAFT

Check for continuity between the commutator and the
armature shaft

Replace the armature if continuity exists between any of
the commutator segments and the armature shaft.

ARMATURE CONTINUITY CHECK -
COMMUTATOR SEGMENTS

Check for continuity between segments. If an open circuit
(no continuity) exists between any two segments, replace
the armature.