Permissible deformation of the mounting structure,
under maximum load for series WD-H slew drives

IMPORTANT

AXIAL DEFLECTION, TILTING, RADIAL EXTENSION
(OR RADIAL CONTRACTION) OF THE MOUNTING
STRUCTURE UNDER MAX. LOAD CAUSES DEFORMA-
TION OF THE MOUNTING STRUCTURE.

SELECTING THE MOUNTING ELEMENTS

ONLY USE MOUNTING ELEMENTS OF THE CORRECT SIZE, NUM-
BER AND QUALITY. DO NOT REUSE BOLTS, NUTS, AND WASH-
ERS. USING UNSUITABLE MOUNTING ELEMENTS MAY CAUSE
THE BOLTED UNION TO FAIL AND THUS THE ENTIRE CONSTRUC-
TION TO FAIL.

Figure 3-191. Do not use continuous thread

The function and service life, as well as the durability of
the bolted union are highly dependent on grip ratio, the
type of bolt, and the dimensions of the bolts. Conse-
quently select the mounting elements on the basis of the
following:

• Do not use any bolts with a fully threaded shaft.
• Only use new, quality class 10.9 (metric) bolts or SAE

Grade 8.

• Maintain the grip ratio (grip length to the diameter of

the bolt) of at least

5 to maximum

10.

• Select bolt length to ensure that the minimum insertion

depth is reached.

• If the permissible interfacial pressure is exceeded use

appropriate washers.

Figure 3-192. Mounting element

Minimum insertion depth depending on fracture
strength of the mounting structure

Size of the slew drive

146

220

300

373

490

625

Permissible deformation of the
mounting structure per support sur-
face

[mm]

0.10

0.11

0.12

0.13

0.15

0.16

[in]

0.0040

0.0044

0.0048

0.0052

0.0059

0.0063

Fracture strength Rm of the
mounting structure

Minimum
insertion depth
(le)

in N/mm²

in lbf/in²

Strength class
10.9 / Grade 8

500 to 700

72520 to 101525

le = 1.4*ds

700 to 900

101525 to 130535

le = 1.1*ds

over 900

over 130535

le = 0.9*ds