SECTION 3 - CHASSIS & TURNTABLE

3121448

– JLG Lift –

3-223

VALVE CLEARANCE

Inspection/adjustment:

Valve clearance inspection and adjustment must be per
formed with the engine cold.

1. Remove the cylinder head cover.

2. With recoil starter type:

Set the piston at top dead center of the compression
stroke (both' valves fully closed) by pulling the recti
starter slowly. The ''∆'' mark on the starter pulley wit
align with the projection on the fan cover when the
pastor is at top dead center of the compression
stroke.

Without retool starter type:

sit the piston at top dead center of the compression
stroke (both valves fully closed) by turning the cool-
ing fan setting plate. The projection of the cooling
fan will align with the projection on the fan cover
when the piston is at top dead center of the com-
pression stroke.

3. Insert a feeler gauge between the rocker arm and

valve to measure valve clearance.

Valve clearance

IN

0.12 ±0.02 mm

EX

0.15 ±0.02 mm