SECTION 3 - CHASSIS & TURNTABLE

3121448

– JLG Lift –

3-251

ARMATURE

Mica depth:

When the mica is fillers or its depth is smaller than the ser-
vice limit value, recut the grooves using: a hacksaw blade
or t small file.

Service limit

0.2 mm (0,01 in)

Continuity check-commutator segments:

Check for continuity between segments. If an open circuit
(no continuity) exists between any two segments, replace
the armature.

Continuity check-commutator to core:

Check for continuity between the commutator segments
and the a rapture coil core. Replace the armature if conti-
nuity exists.

Continuity check-commutator to shaft:

Check for continuity between the commutator and the
armature shaft.

Replace the armature if continuity exists between any of
the commutator segments end the armature shaft.